Drop Testing
Problem Identification:
-
Determining the fail point of the shield's fasteners in the event of a car accident
Procedure:
-
Design a configuration to drop the shield in the X,Y,Z planes
-
This will induce a high G force on the mount points of the shield
-
Hook up accelerometer to shield to record G forces
-
Graph data in excel
-
Determine if there are weak points in mounting design